[1]B. B. Barrow, “IEEE Guide for the Statistical Analysis of Thermal Life Test Data,” IEEE Standard 101-1972, pp. 7-32, June, 1971.
[2]International Electrotechnical Commision, “Power Transformers Temperature Rise,” IEC 76-2, 1993.
[3]I. H. Koponen, “Guide for Loading Mineral Oil-Immersed Power Transformers Up To and Including 100 MVA with 55℃ or 65℃ Winding Rise,” ANSI/IEEE C57.92-1981, January 1981.
[4]IEEE, “IEEE Guide for Determination of Maximun Winding Temperature Rise in Liquid-Filled Transformers,” IEEE Std 1538-2000, 2000.
[5]FLUENT 6.0 Users Guide Documentation, Fluent Inc., Lebanon, New Hampshire, 2001.
[6]吳萬生、張阿專、姜仁雄、陳正彥、周蒼生, 大同變壓器的特性與構造, 大同技術手冊電力技術篇第一冊, 1974, Vol. 1-7, pp. 1-1 – 7-14; Vol. 11-12, pp. 11-1 – 12-19, December 1974.
[7]吳萬生、張阿專、姜仁雄、陳正彥、周蒼生, 大同變壓器的製造與試驗, 大同技術手冊電力技術篇第二冊, 1972, Vol. 2, pp. 2-11 – 2-17; Vol. 21, pp. 21-1 – 21-11, December 1972.
[8]J. J. Winders and Jr. Marcel , “Power Transformer Principles and Applications,” Marcel Dekker, Inc., 2002.
[9]G. L. Alegi and W. Z. Black, “Real-Time Thermal Model For an Oil-Immersed, Forced-Air Cooled Transformer,” IEEE Transactions On Power Delivery, Vol. 5, No. 2, April 1990.
[10]W. H. Tang, Q. H. Wu, and Z. j. Richardson, “Equivalent Heat Circuit Based Power Transformer Thermal Model,” IEE Process-Electronic Power Application, Vol. 149, No. 2, March 2002.
[11]L. W. Pierce, “Predicting Liquid Filled Transformer Loading Capability,” IEEE Transactions On Industry Applications, Vol. 30, No. 1, January/February 1994.
[12]M. V. Thaden, S. P. Mehta, S. C. Tuli, and R. L. Grubb, ”Temperature Rise Tests on a Forced-Oil-Air Cooled (FOA) (OFAF) Core-Form Transformer, Including Loading Beyond Nameplate,” IEEE Transactions On Power Delivery, Vol. 10, No. 2, April 1995.
[13]J. C. S. Fagundes, A. J. Bstisa, and P. Viarouge, “Thermal Modeling of Pot Core Magnetic Components Used in High Frequency Static Converters,” IEEE Transactions On Magnetics, Vol. 33, No. 2, March 1997.
[14]O. M. Zodeh and R. J. Whearty, “Thermal Characteristics of a Meta-Aramid and Celluose Insulated Transformer at Load Beyond Nameplate,” IEEE Transactions On Power Delivery, Vol. 12, No. 1, January 1997.
[15]R. M. Del Vecchio and P. Feghali, “Thermal Model of Disk Coil with Directed Oil Flow,” North American Transformer 1200 Piper Drive Milpitas, CA 95035 USA.
[16]L. W. Pierce and T. Holifield, “A Thermal Model for Optimized Distribution and Small Power Transformer Design,” IEEE, 1999.
[17]Y. Saboohi, “Thermal Model For Operation of Arc Furnace Transformer in Steel Making Plant in a Climate of High Humidity,” IEEE, 2000.
[18]D. J. Tylavsky, Qing He, Jennie Si, G. A. McCulla, and J. R. Hunt, “Transformer Top-Oil Temperature Modeling and Simulation,” IEEE Transactions On Industry Applications, Vol. 36, No. 5, September/October 2000.
[19]G. Swift, T. S. Molinski, R. Bray, and R. Menzies, “A Fundamental Approach to Transformer Thermal Modeling – Part II: Field Verification,” IEEE Transactions On Power Delivery, Vol. 16, No. 2, April 2001.
[20]施俊豪,變壓器內部溫升之研究,國立中央大學機械研究所碩士論文,2001。
[21]許博聞,油浸式電力變壓器溫升之研究,私立中原大學機械工程研究所碩士論文,2003。[22]W. H. Tang, Q. H. Wu, and Z. j. Richardson, “Equivalent Heat Circuit Based Power Transformer Thermal Model,” IEE Process-Electronic Power Application, Vol. 149, No. 2, March 2002.
[23]大同技術手冊電力技術篇第一冊。
[24]http://www.tatung.com/b5/tr/Power/PowerTr1.pdf.
[25]大同技術手冊電力技術篇第二冊。
[26]http://www.docin.com/p-8440742.html.
[27]IEEE, “IEEE Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers,” IEEE Standard C57.12.00-2000, IEEE-SA Standards Board, June 2000.
[28]IEEE, “IEEE Guide for Loading Mineral-Oil-Immersed Transformers,” IEEE Standard C57.91-1995, IEEE-SA Standards Board, June 1995.
[29]IEEE, “IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers,” IEEE Standard C57.12.90-1999, IEEE Standards Board, June 1999.